Application
The cables are designed to give good protection to the cable cores against inductive interference (RF=0.3). The cables are used for outdoor signaling equipment.
Normes
• RENFE E.T. 03.365.051.6
Construction
Conductors
Solid annealed bare copper 0.9/1.4mm as per ASTM B-3/class 1 of IEC 60228
Isolation
Solid polyethylene as per ASTM D 1248/IEC 60708
Twisted Pairs
Two insulated conductors are twisted into pairs with varying lays to minimize crosstalk
Cable Core Assemblée
The cores are cabled together in concentric layers to form the cable core. Units are identified by colour coded binders
Core remplissage (optional)
The cable core interstices can be filled with petroleum jelly to avoid longitudinal water penetration inside the cable
Core Wrapping
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap
Moisture Barrier (optional)
An optional copolymer coated aluminium tape of 0.2mm is applied longitudinally with an overlap
Literie
PE or LSZH
Electrostatic Screen
Corrugated copper tape of 0.12mm is applied longitudinally with overlap
Electrostatic Armour
Two high permeability steel tapes of 0.5mm are helically applied with gap. The outer tape will cover the gap left by the inner one
Gaine
PVC or LSZH
Ripcord
Nylon ripcord may be placed parallel to the cores to facilitate sheath removal
Electrical Properties
Mechanical and Thermal Properties
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 15 x Overall Diameter
Colour Code
Position |
Nombre de paires |
1(Pilot) |
2(Direct) |
3 |
4 |
5 |
Centre |
BLACK |
NATURAL |
BLUE |
NATURAL |
YELLOW |
NATURAL |
RED |
NATURAL |
|
|
Layers |
BLACK |
NATURAL |
BLUE |
NATURAL |
YELLOW |
NATURAL |
RED |
NATURAL |
GREEN |
NATURAL |
Dimensions And Weight
Cable Code |
Number of Pairs |
Nominal Literie/
Gaine Epaisseur
mm |
Diamètre nominal
mm |
Poids nominal
kg/km |
0.9mm Conductor, 1.8mm Insulated Wire |
TP365-2Y2Y(CTS)2Y(DSTA)Y2P09-RF03 |
2 |
1.5/1.6 |
18.3 |
1300 |
TP365-2Y2Y(CTS)2Y(DSTA)Y6P09-RF03 |
6 |
1.5/1.6 |
21.7 |
1425 |
TP365-2Y2Y(CTS)2Y(DSTA)Y10P09-RF03 |
10 |
1.5/1.6 |
25.2 |
1650 |
TP365-2Y2Y(CTS)2Y(DSTA)Y14P09-RF03 |
14 |
1.5/1.6 |
26.7 |
1800 |
TP365-2Y2Y(CTS)2Y(DSTA)Y20P09-RF03 |
20 |
1.5/1.6 |
29.2 |
2275 |
TP365-2Y2Y(CTS)2Y(DSTA)Y28P09-RF03 |
28 |
1.6/1.8 |
32.3 |
2450 |
TP365-2Y2Y(CTS)2Y(DSTA)Y38P09-RF03 |
38 |
1.7/1.8 |
36.0 |
2895 |
TP365-2Y2Y(CTS)2Y(DSTA)Y54P09-RF03 |
54 |
1.7/1.8 |
40.5 |
3275 |
TP365-2Y2Y(CTS)2Y(DSTA)Y74P09-RF03 |
74 |
1.8/2.0 |
45.6 |
3775 |
TP365-2Y2Y(CTS)2Y(DSTA)Y96P09-RF03 |
96 |
1.9/2.0 |
49.8 |
4275 |
1.4mm Conductor, 2.7mm Insulated Wire |
TP365-2Y2Y(CTS)2Y(DSTA)Y2P14-RF03 |
2 |
1.5/1.6 |
20.2 |
1615 |
TP365-2Y2Y(CTS)2Y(DSTA)Y6P14-RF03 |
6 |
1.5/1.6 |
25.7 |
1775 |
TP365-2Y2Y(CTS)2Y(DSTA)Y10P14-RF03 |
10 |
1.6/1.8 |
30.8 |
2200 |
TP365-2Y2Y(CTS)2Y(DSTA)Y14P14-RF03 |
14 |
1.6/1.8 |
32.8 |
2525 |
TP365-2Y2Y(CTS)2Y(DSTA)Y20P14-RF03 |
20 |
1.7/1.8 |
36.5 |
2975 |
TP365-2Y2Y(CTS)2Y(DSTA)Y28P14-RF03 |
28 |
1.7/1.8 |
40.5 |
3150 |
TP365-2Y2Y(CTS)2Y(DSTA)Y38P14-RF03 |
38 |
1.8/2.0 |
45.6 |
3695 |
TP365-2Y2Y(CTS)2Y(DSTA)Y58P14-RF03 |
58 |
2.0/2.2 |
52.3 |
3975 |
TP365-2Y2Y(CTS)2Y(DSTA)Y74P14-RF03 |
74 |
2.1/2.2 |
59.1 |
4475 |
TP365-2Y2Y(CTS)2Y(DSTA)Y96P14-RF03 |
96 |
2.2/2.3 |
66.0 |
4975 |